TSUCHIYA Ken
Department School of Medicine(Tokyo Women's Medical University Hospital), School of Medicine Position Professor (Fixed Term) |
|
Article types | Original article |
Language | English |
Peer review | Non peer reviewed |
Title | Minimum-incision transsubclavian transcatheter aortic valve replacement with balloon-expandable valve for dialysis patients |
Journal | Formal name:Journal of cardiology Abbreviation:J Cardiol ISSN code:18764738/09145087 |
Domestic / Foregin | Foregin |
Volume, Issue, Page | 84(2),pp.93-98 |
Author and coauthor | Domoto Satoru, Yamaguchi Junichi, Tsuchiya Ken, Inagaki Yusuke, Nakamae Kosuke, Hirota Masataka, Arashi Hiroyuki, Hanafusa Norio, Hoshino Junichi, Niinami Hiroshi |
Publication date | 2024/08 |
Summary | BACKGROUND:Dialysis patients undergoing transcatheter aortic valve replacement (TAVR) face increased risk and have poorer outcomes than non-dialysis patients. Moreover, TAVR in dialysis patients using an alternative approach is considered extremely risky and little is known about the outcomes. We routinely perform minimum-incision transsubclavian TAVR (MITS-TAVR), which is contraindicated for transfemoral (TF) TAVR. This study aimed to evaluate the outcomes of MITS-TAVR compared with those of TF-TAVR in dialysis patients.
METHODS:This single-center, observational study included 79 consecutive dialysis patients who underwent MITS-TAVR (MITS group, n = 22) or TF-TAVR (TF group, n = 57) under regional anesthesia. CONCLUSION:The outcome of MITS-TAVR was comparable to that of TF-TAVR in dialysis patients, despite the higher risk of patient characteristics. |
DOI | 10.1016/j.jjcc.2024.01.001 |
PMID | 38215966 |