キシノ マイコ   KISHINO Maiko
  岸野 真衣子
   所属   医学部 医学科(東京女子医科大学病院)
   職種   講師
論文種別 症例報告
言語種別 英語
査読の有無 査読なし
表題 Endoscopic Image 2 Hours after PuraStat® Application: A Case of Achieving Hemostasis Using PuraStat® for Postgastric Lesion Biopsy Bleeding after Hemostatic Clips Failed.
掲載誌名 正式名:Case reports in gastrointestinal medicine
略  称:Case Rep Gastrointest Med
ISSNコード:20906528
掲載区分国外
巻・号・頁 2023,pp.5620348
著者・共著者 MISUMI Yoshitsugu, NONAKA Kouichi, KISHINO Maiko
担当区分 最終著者
発行年月 2023/07
概要 PuraStat® (3D Matrix, Tokyo, Japan) is a novel, self-assembling peptide hemostatic hydrogel that can be used endoscopically. Hemostasis can be physically obtained by covering bleeding points; however, there are no reports of how long PuraStat remains in the upper gastrointestinal tract. Herein, we report a case wherein esophagogastroduodenoscopy (EGD) was performed 2 hours after PuraStat application. A 73-year-old man underwent EGD for evaluation of lesions in the posterior wall of the stomach. A biopsy was then performed on the gastric lesions; however, massive bleeding occurred. A hemostatic clip was used to stop bleeding but failed; primary hemostasis was obtained by applying PuraStat. EGD performed 2 hours later to determine whether the patient could be discharged revealed that the white-turning PuraStat gel remained firmly in the applied area, confirming complete hemostasis. PuraStat is a hemostatic agent capable of physical hemostasis that reliably remains in the stomach even after a few hours of use and, thus, may replace some conventional hemostasis methods.
DOI 10.1155/2023/5620348
PMID 37547442