伊藤 淳哉
   Department   School of Medicine(Tokyo Women's Medical University Hospital), School of Medicine
   Position   Assistant Professor
Article types Original article
Language English
Peer review Peer reviewed
Title AP3×ML3 reduction quality classification for femoral trochanteric fractures: validation for reliability focusing on positive medial cortical support.
Journal Formal name:Journal of orthopaedic surgery and research
Abbreviation:J Orthop Surg Res
ISSN code:1749799X/1749799X
Domestic / ForeginForegin
Volume, Issue, Page 18(1),pp.64
Author and coauthor Itou Junya, Kuramitsu Yujiro, Hatta Satoshi, Okazaki Ken
Authorship Lead author
Publication date 2023/01
Summary INTRODUCTION:This study evaluated the validity of the AP3 × ML3 reduction quality classification, which applies the concept of positive medial cortical support.METHODS:A total of 120 trochanteric fractures classified as AO Foundation/Orthopedic Trauma Association 31A1 and A2 were retrospectively analyzed. The validity of the AP3 × ML3 classification was evaluated by comparison with the Baumgaertner reduction quality criteria. When using the AP3 × ML3 classification, reduction quality was divided into three classes based on the degree of anterior cortical contact between the proximal and distal fragments. Reduction quality was also divided into three classes when using the Baumgaertner criteria. The frequency of mechanical complications, including cut-out, delayed union, and excessive migration of the lag screw, was retrospectively assessed. Intra-observer and inter-observer reliability was assessed using the intraclass correlation coefficient (ICC).RESULTS:Mechanical complications included 4 cases of cutout (3.3%) and 1 of delayed union (0.8%). Mechanical complications occurred for all levels of reduction quality in both classifications, except for the acceptable of the Baumgaertner criteria. When reduction quality was rated as good, acceptable, and poor the incidence of mechanical complications was 2.5%, 5.7%, and 16%, respectively, under the AP3 × ML3 classification and 3.3%, 0%, and 15.0%, respectively, under the Baumgaertner criteria. The ICC was 0.80 for intra-observer reliability and 0.57 for inter-observer reliability when using the AP3 × ML3 classification and 0.85 and 0.34, respectively, when using the Baumgaertner criteria.CONCLUSION:The AP3 × ML3 classification was reliable and easy to use compared with the widely used Baumgaertner reduction quality criteria. Level of evidence 4.
DOI 10.1186/s13018-023-03555-5
PMID 36694258