キンジヨウ タカヒコ   Kinjiyou Takahiko
  金城 貴彦
   所属   医学部 医学科(東京女子医科大学病院)
   職種   助教
論文種別 症例報告
言語種別 英語
査読の有無 査読あり
表題 Great cardiac vein occlusion following radiofrequency catheter ablation: a late complication identified during cardiac device implantation
掲載誌名 正式名:Eur Heart J Cardiovasc Imaging
ISSNコード:20472404
掲載区分国外
巻・号・頁 24,pp.e115
著者・共著者 Takahiko Kinjo,†* Shingo Sasaki, Masaomi Kimura, Hirofumi Tomita
担当区分 筆頭著者,責任著者
発行年月 2023/06
概要 A 67-year-old man with ischaemic cardiomyopathy was admitted to our hospital. Pulmonary vein isolation for persistent atrial fibrillation and radiofrequency (RF) catheter ablation for peri-mitral atrial tachycardia from the endocardial and epicardial via the great cardiac vein (GCV) were performed. A total of seven RF applications were applied (15–20 W, 10 s each) from inside the GCV using an irrigated-tip catheter (triangles in panel A). Even after undergoing coronary artery bypass, percutaneous transcatheter mitral valve repair for functional mitral regurgitation, and optimal medical therapy, left ventricular ejection fraction (LVEF) was not improved. Therefore, 1 year after ablation, he received cardiac resynchronization therapy with defibrillator (CRT-D) for low LVEF (30%), intraventricular conduction disturbance, and non-sustained ventricular tachycardia. During implantation, venography revealed the occlusion of the GCV (triangles in panel B). A post hoc review of the post-surgery computer tomography (CT) showed the sudden interruption of the GCV (triangles in panel C), suggesting the occlusion of the GCV. The left ventricular lead was implanted at the postero-lateral vein (arrows in panel D), which branches from the proximal of GCV.
DOI 10.1093/ehjci/jead073
文献番号 37073793