ミスミ ヨシツグ
Misumi Yoshitsugu
三角 宜嗣 所属 医学部 医学科(東京女子医科大学病院) 職種 助教 |
|
論文種別 | 症例報告 |
言語種別 | 英語 |
査読の有無 | 査読なし |
表題 | Endoscopic Image 2 Hours after PuraStat® Application: A Case of Achieving Hemostasis Using PuraStat® for Postgastric Lesion Biopsy Bleeding after Hemostatic Clips Failed. |
掲載誌名 | 正式名:Case reports in gastrointestinal medicine 略 称:Case Rep Gastrointest Med ISSNコード:20906528 |
掲載区分 | 国外 |
巻・号・頁 | 2023,pp.5620348 |
著者・共著者 | MISUMI Yoshitsugu, NONAKA Kouichi, KISHINO Maiko |
担当区分 | 筆頭著者,責任著者 |
発行年月 | 2023/07 |
概要 | PuraStat® (3D Matrix, Tokyo, Japan) is a novel, self-assembling peptide hemostatic hydrogel that can be used endoscopically. Hemostasis can be physically obtained by covering bleeding points; however, there are no reports of how long PuraStat remains in the upper gastrointestinal tract. Herein, we report a case wherein esophagogastroduodenoscopy (EGD) was performed 2 hours after PuraStat application. A 73-year-old man underwent EGD for evaluation of lesions in the posterior wall of the stomach. A biopsy was then performed on the gastric lesions; however, massive bleeding occurred. A hemostatic clip was used to stop bleeding but failed; primary hemostasis was obtained by applying PuraStat. EGD performed 2 hours later to determine whether the patient could be discharged revealed that the white-turning PuraStat gel remained firmly in the applied area, confirming complete hemostasis. PuraStat is a hemostatic agent capable of physical hemostasis that reliably remains in the stomach even after a few hours of use and, thus, may replace some conventional hemostasis methods. |
DOI | 10.1155/2023/5620348 |
PMID | 37547442 |