ムラガキ ヨシヒロ
Muragaki Yoshihiro
村垣 善浩 所属 医学部 医学科(東京女子医科大学病院) 職種 客員教授 |
|
論文種別 | 原著 |
言語種別 | 英語 |
査読の有無 | 査読あり |
表題 | Surgery assistance system for continuous resection of brain tumors-proposal of continuous tumor resection forceps, tumor cell separation, dehydration, and isolation mechanism. |
掲載誌名 | 正式名:International journal of computer assisted radiology and surgery 略 称:Int J Comput Assist Radiol Surg ISSNコード:18616429/18616410 |
掲載区分 | 国外 |
巻・号・頁 | 18(5),pp.877-885 |
著者・共著者 | KOGUCHI Taro†, SHIMIZU Fumika, NAGAME Tomohiro, GOTO Yuka, IWASAKI Hikaru, HANAFUSA Akihiko, TAKAGI Motoki,MOHAMADDAN Shahrol, NOMURA Kenichi, MURAGAKI Yoshihiro, ISEKI Hiroshi, MASAMUNE Ken, AKITAYA Toyohisa |
発行年月 | 2023/05 |
概要 | The tumor resection ratio must be improved due the increased possibility of recurrence or malignancy. The purpose of this study was to develop a system that includes forceps with a continuous suction function and flow cytometry to diagnose the malignancy of the tumor for safe, accurate, and effective surgery. A newly developed continuous tumor resection forceps consists of a triple pipe structure, which enables continuous suction of the tumor by integrating the reflux water and suction system. The forceps includes tip opening/closure detection switch to control the adsorption and suction strength when tip is opened and closed. To perform accurate tumor diagnosis using flow cytometry, a filtering mechanism was developed for dehydrating reflux water from continuous suction forceps. In addition, a cell isolation mechanism comprising a roller pump and shear force loading mechanism was also newly developed. By using a triple pipe structure, a significantly larger tumor collection ratio was observed compared to the previous double-pipe structure. By performing suction pressure control with the opening/closure detection switch, inaccurate suction can be prevented. By widening the filter area of dehydration mechanism, it was possible to improve the reflux water dehydration ratio. The most appropriate filter area was 85 mm2. By using a newly developed cell isolation mechanism, the processing time can be reduced to less than 1/10 of the original time, keeping the same cell isolation ratio, when compared to the existing pipetting method. Neurosurgery assistance system with continuous tumor resection forceps and a cell separation, dehydration and isolation mechanism was developed. An effective and safe tumor resection, accurate and fast diagnosis of malignancy can be achieved by using the current system. |
DOI | 10.1007/s11548-023-02845-x |
PMID | 36809456 |